beautypg.com

Table 4-16, Logged error events, Bios – Artesyn ATCA-8330 Installation and Use (April 2015) User Manual

Page 92

background image

BIOS

ATCA-8330 Installation and Use (6806800S82B)

92

For correctable memory error logging, there are two additional parameters to prevent the
flooding of the event logs. The parameters are:

Error Threshold - Correctable memory errors are logged when the threshold is reached.
The first correctable memory error is always logged.

Error Logging Limit - The number of logged correctable memory errors for a DIMM is
limited. If the last entry in the log is SMBIOS: 'Correctable memory log disabled' and IPMI:
Memory event 'Correctable ECC logging limit reached'. No further correctable errors are
logged for this DIMM.

Table 4-16 Logged Error Events

Error

SMIBIOS

IPMI

Correctable:
- Correctable ECC Memory Error

Single-bit ECC memory error

Sensor: Memory, Offset 00h

Correctable:
- Memory Error Limit Reached
- Correctable ECC logging limit reached

Correctable memory log disabled

Sensor: Memory, Offset 05h

Uncorrectable:
- Uncorrectable ECC Memory Error

Multi-bit ECC memory error

Sensor: Memory, Offset 01h

PCI PERR

PCI Parity Error

Sensor: Critical Interrupt,
Offset 04h PCI PERR

PCI SERR

PCI System Error

Sensor: Critical Interrupt,
Offset 05h PCI SERR