beautypg.com

3 mechanical data, Table 1-2, Mechanical data – Artesyn ATCA-8330 Installation and Use (April 2015) User Manual

Page 36: Introduction

background image

Introduction

ATCA-8330 Installation and Use (6806800S82B)

36

1.3

Mechanical Data

The following table provides details about the mechanical data of the blade, such as
dimensions and weight.

To fulfill the requirements of Telcordia GR-1089,R4-14, use Shielded Twisted Pair (STP)
cables grounded at both ends to connect to the Ethernet ports.

This blade contains an embedded power source rated >150W. To achieve NEBS
compliance on system level, Shelf Ground (chassis ground) and Logic Ground (logic
signal return) have to be connected. The connection may be implemented inside the
shelf, for example at the backplane, or the shelf has to provide a possibility to lead Logic
Ground out of the shelf for external connection to Central Office Ground. For further
information refer to Telcordia GR-1089-CORE, section 9.8.2, requirement R9-14.

The product has been designed to meet the directive on the restriction of the use of
certain hazardous substances in electrical and electronic equipment (RoHS) Directive
2002/95/EC.

Table 1-2 Mechanical Data

Feature

Value

Dimensions (width x height x depth)

30 mm x 351 mm x 312 mm
8U form factor

Weight of blade

3.2 Kg.