beautypg.com

Table 2-1, Environmental requirements, Hardware preparation and installation – Artesyn ATCA-8330 Installation and Use (April 2015) User Manual

Page 41

background image

Hardware Preparation and Installation

ATCA-8330 Installation and Use (6806800S82B)

41

Table 2-1 Environmental Requirements

Requirement

Operating

Non-Operating

Temperature

+5 °C (41 °F) to +40 °C (104 °F) (normal
operation) according to NEBS Standard
GR-63-CORE
-5 °C (23 °F) to +55 °C (131 °F)
(exceptional operation) according to
NEBS Standard GR-63-CORE

-40 °C (-40 °F) to +70 °C (158 °F) (may be
further limited by installed accessories)

Temp. Change

+/- 0.25 °C/min according to NEBS
Standard GR-63-CORE

+/- 0.25 °C/min

Rel. Humidity

5% to 90% non-condensing according
to Artesyn-internal environmental
requirements

5% to 95% non-condensing according to
Artesyn-internal environmental
requirements

Vibration

0.1 g from 5 to 100 Hz and back to 5 Hz
at a rate of 0.1 octave/minute

5-20 Hz at 0.01 g

2

/Hz

20-200 Hz at -3.0 dB/octave
Random 5-20 Hz at 1 m

2

/Sec

3

Random 20-200 Hz at -3 m/Sec

2

Shock

Half-sine, 11 m/Sec, 30mSec/Sec

2

Blade level packaging
Half-sine, 6 mSec at 180 m/Sec

2

Free Fall

-

1,200 mm/all edges and corners
1.0 m (packaged) per ETSI 300 019-2-2
(blade level packaging)
100 mm (unpacked) per GR-63-CORE