Intelligent Peripheral Management Controller
ATCA-8330 Installation and Use (6806800S82B)
138
7.3.4
HPM.1 Firmware Upgrade Tool
The primary update mechanism for the ATCA-8330 blades is the FCU tool, which is delivered
with the BBS package for the board. For more information about firmware update, refer BBS
Manual.
7.3.5
Manual Rollback
To be able to switch from an active component to its rollback version, the HPM1 command
Initiate Manual Rollback is enhanced with a 2 request data argument to enable users to select
the component which should be rollbacked. This is done to overcome a limitation in the HPM1
specification. Using this command extension, component rollback can be initiated always
without previous firmware upgrades.
7.3.6
Retrieving Versioning Information
Retrieving the actual and backup version of the components is possible without switching
payload firmware boot banks (Artesyn Embedded Technologies - Embedded Computing
strongly recommends to use fcu for embedded firmware upgrades). The following terminal
output illustrates the component versions as an example:
********************[[[[[REPORT BEGIN]]]]]********************
Operation: Query
#00 Device : IPMC F/W
Bank #0 - Active Version: 2.00.00000005
Bank #1 - Rollback Version: 2.00.00000005
Capabilities :
Upgrade operation : (x)
Mark operation : ( )
Activate operation : (x)
Compare operation : ( )
Service affected : (x)
Manual Rollback : (x)
Automatic Rollback : (x)
Self Test : (x)
Properties :