1 environmental requirements, Table 2-1, Environmental requirements – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual
Page 43: Hardware preparation and installation

Hardware Preparation and Installation
ATCA-7368 Installation and Use (6806800M12D)
43
2.3.1
Environmental Requirements
The environmental conditions must be tested and proven in the shelf configuration used. The
conditions refer to the surrounding of the blade within the user environment.
Table 2-1 Environmental Requirements
Requirement
Operating
Non-Operating
Temperature
Normal Operation: +5 °C (41 °F) to +40
°C (104 °F) according to Telcordia GR-
63-CORE (NEBS) and ETSI EN 300 019-
1-3, Class 3.1
Exceptional Operation: -5 °C (23 °F) to
+55 °C (131 °F) according to Telcordia
GR-63-CORE (NEBS)
Note: This exceeds ETSI EN 300 019-1-
3, Class 3.1E requirements (-5°C to
+45°C)
-40 °C (-40 °F) to +70 °C (158 °F) according
to Telcordia GR-63-CORE (NEBS) and ETSI
EN 300 019-1-2, Class 2.3
Note: This exceeds ETSI EN 300 019-1-1,
Class 1.2 requirements (storage from -
25 °C to +55 °C
Note: This may be further limited by
installed accessories.
Temp. Change
+/- 0.25 °C/min according to Telcordia
GR-63-CORE
+/- 0.25 °C/min
Rel. Humidity
Normal Operation: 5%rH to 85%rh non-
condensing
Exceptional Operation: 5%rH to 90%rh
non-condensing
According to Telcordia GR-63-CORE
(NEBS) and EN 300 019-1-3, Classes 3.1
and 3.1E
5% to 95% non-condensing according to
Telcordia GR-63-CORE (NEBS) and EN 300
019-1-1, Classes 1.2 and 2.3
Vibration
1g from 5 to 200Hz and back to 5Hz at
a rate of 0.25 octave/minute
(according to Telcordia GR-63-core)
5-20 Hz at 0.01 g
2
/Hz (according to
Telcordia GR-63-core and ETSI EN 300
019-2-2)
20-200 Hz at -3 dB/octave Hz (according
to Telcordia GR-63-core and ETSI EN 300
019-2-2)
Random 5-20Hz at 1 m
2
/s
3
Random 20-200Hz at 3 m
2
/s
3
Shock
Half-sine, 11 ms, 30 m/s
2
Blade level packaging
Half-sine, 6 ms at 180 m/s
2