beautypg.com

5 fru inventory commands, 6 sensor device commands, Table 7-5 – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual

Page 106: Supported fru inventory commands, Table 7-6, Supported sensor device commands, Supported ipmi commands

background image

Supported IPMI Commands

ATCA-7368 Installation and Use (6806800M12D)

106

7.2.5

FRU Inventory Commands

7.2.6

Sensor Device Commands

Table 7-5 Supported FRU Inventory Commands

Command

NetFn (Request/Response)

CMD

Get FRU Inventory Area Info

0x0A/0x0B

0x10

Read FRU Data

0x0A/0x0B

0x11

Write FRU Data

0x0A/0x0B

0x12

Table 7-6 Supported Sensor Device Commands

Command

NetFn
(Request/Response) CMD

Comments

Get Device SDR Info

0x04/0x05

0x20

-

Get Device SDR

0x04/0x05

0x21

-

Reserve Device SDR Repository

0x04/0x05

0x22

-

Get Sensor Reading Factors

0x04/0x05

0x23

-

Set Sensor Hysteresis

0x04/0x05

0x24

-

Get Sensor Hysteresis

0x04/0x05

0x25

-

Set Sensor Threshold

0x04/0x05

0x26

Most of the threshold-based
sensors have fixed thresholds.
Before using this command,
check whether threshold
setting is supported by using
the Get Device SDR command.

Get Sensor Threshold

0x04/0x05

0x27

-

Set Sensor Event Enable

0x04/0x05

0x28

-

Get Sensor Event Enable

0x04/0x05

0x29

-

Get Sensor Event Status

0x04/0x05

0x2B

-

This manual is related to the following products: