Table 8-29, Fru information and sdr summary – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual
Page 188

FRU Information and SDR Summary
ATCA-7368 Installation and Use (6806800M12D)
188
Nominal Reading
0x9A
1.5
Upper non-recoverable
threshold
0xAB 1.7
Upper critical threshold
0xA3
1.6
Upper non-critical
threshold
0x00 (unspecified)
Lower non-recoverable
threshold
0x89 1.4
Lower critical threshold
0x90
1.3
Lower non-critical
threshold
0x00 (unspecified)
Reading Definition
Analog reading byte
Analog sensor reading
Table 8-29 1.2V
Feature
Raw Value
Description
Sensor Name
1.2V
-
Sensor LUN
0x00
-
Sensor Number
0x18
-
Entity ID
0x14
power module / DC-to-DC
converter
Sensor Type
0x02
Voltage
Event/Reading Type
0x01
Threshold
Assertion Event Mask
(Byte 15)
0x14 -
Assertion Event Mask
(Byte 16)
0x6A -
Deassertion Event Mask
(Byte 17)
0x14 -
Deassertion Event Mask
(Byte 18)
0x6A -
Table 8-28 1.5V (continued)
Feature
Raw Value
Description