Table 8-23, Ddr 6 temp, 0x1b see – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual
Page 180: Fru information and sdr summary
FRU Information and SDR Summary
ATCA-7368 Installation and Use (6806800M12D)
180
Rearm mode
0x01
Auto
Hysteresis Support
0x02
Readable and settable
Threshold Access
Support
0x02
Readable and settable
Event Message Control
0x00
Per Threshold/Discrete
State
Nominal Reading
0x28
40
Upper non-recoverable
threshold
0x5F 95
Upper critical threshold
0x55
85
Upper non-critical
threshold
0x4B 75
Lower non-recoverable
threshold
0x00 (unspecified)
Lower critical threshold
0x00
(unspecified)
Lower non-critical
threshold
0x00 (unspecified)
Reading Definition
Analog reading byte
Analog sensor reading
Table 8-23 DDR 6 Temp
Feature
Raw Value
Description
Sensor Name
DDR 6 Temp
-
Sensor LUN
0x00
-
Sensor Number
0x12
-
Entity ID
0xA0
PICMG Front Board
Sensor Type
0x01
Temperature
Event/Reading Type
0x01
Threshold
Table 8-22 DDR 5 Temp (continued)
Feature
Raw Value
Description