beautypg.com

Table 8-46, Sensor data records, Fru information and sdr summary – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual

Page 206

background image

FRU Information and SDR Summary

ATCA-7368 Installation and Use (6806800M12D)

206

For sensor threshold definition, use the "ipmitool" available at

http://sourceforge.net/projects/ipmitool/files/ipmitool/

with the

parameter "sensor".

Table 8-46 Sensor Data Records

Sensor

Number Sensor Name

Sensor Type

Event/Reading

Type

Event Data Byte 1

Event Data Byte 2

Event Data Byte 3

Event

Threshold/Description

Assertion

Deassertion

Rearm

0x00

HS Carrier

Hot Swap 0xF0 Sensor-specific

discrete
0x6F

[7:4] = See IPMC Spec
[3:0] = Current State (0, 1,

2, 3, 4, 5, 6 or 7)

[7:4] = Cause of

State
[3:0] = Previous

State

[7:0] =FRU Device

ID

For the Field: Current

State/Previous State
0x0: M0
0x1: M1
0x2: M2
0x3: M3
0x4: M4
0x5: M5
0x6: M6
0x7: M7

Asrt

Auto

0x01

HS AMC

Hot Swap
0xF0

Sensor-specific
discrete
0x6F

[7:4] = See IPMC Spec
[3:0] = Current State (0, 1,

2, 3, 4, 5, 6 or 7)

[7:4] = Cause of state

change
[3:0] = Previous

State

[7:0] =FRU Device

ID

For the Field: Current

State/Previous State
0x0: M0
0x1: M1
0x2: M2
0x3: M3
0x4: M4
0x5: M5
0x6: M6
0x7: M7

Asrt

Auto

Asrt: Assertion Unr: Upper non-recoverable threshold Uc: Upper critical threshold Unc: Upper non-critical threshold
Deass: Deassertion Lnr: Lower non-recoverable threshold Lc: Lower critical threshold Lnc: Lower non-critical threshold

This manual is related to the following products: