Table 7-27, Request data of get serial output command, Table 7-28 – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual
Page 126: Response data of get serial output command, Supported ipmi commands
![background image](https://www.manualsdir.com/files/772447/content/doc126.png)
Supported IPMI Commands
ATCA-7368 Installation and Use (6806800M12D)
126
7.4.2.2.1 Request Data
The following table lists the request data applicable to the Get Serial Output command.
7.4.2.2.2 Response Data
The following table lists the response data applicable to the Get Serial Output command.
Table 7-27 Request Data of Get Serial Output Command
Byte
Data Field
1
LSB of Artesyn IANA Enterprise number. A value of 0xCD has to be used.
2
Second byte of Artesyn IANA Enterprise number. A value of 0x65 has to be used.
3
MSB of Artesyn Embedded Technologies IANA Enterprise number. A value of 0x00 has
to be used.
4
Serial connector type
0: faceplate connector
1: Backplane connector
All other values are reserved.
Note: Only the faceplate connector is supported. No connector on the RTM available.
5
Serial connector instance number. A sequential number that starts from "0".
Table 7-28 Response Data of Get Serial Output Command
Byte
Data Field
1
Completion code
2
LSB of Artesyn Embedded Technologies IANA Enterprise number.
3
Second byte of Artesyn Embedded Technologies IANA Enterprise number.
4
MSB of Artesyn Embedded Technologies IANA Enterprise number.
5
Serial output selector