FRU Information and SDR Summary

ATCA-7368 Installation and Use (6806800M12D)

183

Lower non-recoverable
threshold

0xAD 10.7

Lower critical threshold

0xB8

10.1

Lower non-critical
threshold

0x00 (unspecified)

Reading Definition

Analog reading byte

Analog sensor reading

Table 8-25 3.3V

Feature

Raw Value

Description

Sensor Name

3.3V

-

Sensor LUN

0x00

-

Sensor Number

0x14

-

Entity ID

0x14

power module / DC-to-DC
converter

Sensor Type

0x02

Voltage

Event/Reading Type

0x01

Threshold

Assertion Event Mask
(Byte 15)

0x14 -

Assertion Event Mask
(Byte 16)

0x6A -

Deassertion Event Mask
(Byte 17)

0x14 -

Deassertion Event Mask
(Byte 18)

0x6A -

Threshold Mask (Byte 19) 0x36

-

Threshold Mask (Byte 20) 0x36

-

Base Unit

0x04

Volts

Rearm mode

0x01

Auto

Hysteresis Support

0x02

Readable and settable

Table 8-24 12.0V (continued)

Feature

Raw Value

Description