Table 8-25, Fru information and sdr summary – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual
Page 183
![background image](https://www.manualsdir.com/files/772447/content/doc183.png)
FRU Information and SDR Summary
ATCA-7368 Installation and Use (6806800M12D)
183
Lower non-recoverable
threshold
0xAD 10.7
Lower critical threshold
0xB8
10.1
Lower non-critical
threshold
0x00 (unspecified)
Reading Definition
Analog reading byte
Analog sensor reading
Table 8-25 3.3V
Feature
Raw Value
Description
Sensor Name
3.3V
-
Sensor LUN
0x00
-
Sensor Number
0x14
-
Entity ID
0x14
power module / DC-to-DC
converter
Sensor Type
0x02
Voltage
Event/Reading Type
0x01
Threshold
Assertion Event Mask
(Byte 15)
0x14 -
Assertion Event Mask
(Byte 16)
0x6A -
Deassertion Event Mask
(Byte 17)
0x14 -
Deassertion Event Mask
(Byte 18)
0x6A -
Threshold Mask (Byte 19) 0x36
-
Threshold Mask (Byte 20) 0x36
-
Base Unit
0x04
Volts
Rearm mode
0x01
Auto
Hysteresis Support
0x02
Readable and settable
Table 8-24 12.0V (continued)
Feature
Raw Value
Description