1 get status command, Table 7-30, Ipmc modes – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual
Page 128: Table 7-31, Get status command description, Supported ipmi commands
Supported IPMI Commands
ATCA-7368 Installation and Use (6806800M12D)
128
Some of the following commands refer to IPMC modes which are defined as follows:
7.5.1
Get Status Command
The Get Status command can be used by the payload software to retrieve the status of the
IPMC.
Reset Carrier SDR repository
0x2E/0x2F
0x33
Table 7-30 IPMC Modes
Mode
Description
Standalone
In standalone mode, the carrier IPMC disconnects from IPMB-0 but keeps on
listening to the serial debug and payload interfaces and serving requests
coming from them, as well as managing the modules, AMC point-to-point
(P2P) and clock E-keying. Standalone mode is intended for debugging
purposes and/or operation in a non-ATCA environment. In standalone mode,
the carrier IPMC automatically activates and deactivates the on-carrier
payload and modules whenever it does not violate any carrier limitations.
Manual standalone
Manual standalone mode is equivalent to standalone mode with only one
exception: carrier IPMC control over the on-carrier payload is automatically
disabled in manual standalone mode.
Table 7-29 Pigeon Point Extension Commands (continued)
Command
NetFn
(Request/Response)
CMD
Table 7-31 Get Status Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00