Table 8-26, 3v mgmt, Fru information and sdr summary – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual
Page 184
FRU Information and SDR Summary
ATCA-7368 Installation and Use (6806800M12D)
184
Threshold Access
Support
0x02
Readable and settable
Event Message Control
0x00
Per Threshold/Discrete
State
Nominal Reading
0xAB
3.3
Upper non-recoverable
threshold
0xBD 3.7
Upper critical threshold
0xB5
3.5
Upper non-critical
threshold
0x00 (unspecified)
Lower non-recoverable
threshold
0x98 3.1
Lower critical threshold
0xA0
2.9
Lower non-critical
threshold
0x00 (unspecified)
Reading Definition
Analog reading byte
Analog sensor reading
Table 8-26 3.3V Mgmt
Feature
Raw Value
Description
Sensor Name
3.3V Mgmt
-
Sensor LUN
0x00
-
Sensor Number
0x15
-
Entity ID
0x14
power module / DC-to-DC
converter
Sensor Type
0x02
Voltage
Event/Reading Type
0x01
Threshold
Assertion Event Mask
(Byte 15)
0x14 -
Assertion Event Mask
(Byte 16)
0x6A -
Table 8-25 3.3V (continued)
Feature
Raw Value
Description