beautypg.com

Table 8-26, 3v mgmt, Fru information and sdr summary – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual

Page 184

background image

FRU Information and SDR Summary

ATCA-7368 Installation and Use (6806800M12D)

184

Threshold Access
Support

0x02

Readable and settable

Event Message Control

0x00

Per Threshold/Discrete
State

Nominal Reading

0xAB

3.3

Upper non-recoverable
threshold

0xBD 3.7

Upper critical threshold

0xB5

3.5

Upper non-critical
threshold

0x00 (unspecified)

Lower non-recoverable
threshold

0x98 3.1

Lower critical threshold

0xA0

2.9

Lower non-critical
threshold

0x00 (unspecified)

Reading Definition

Analog reading byte

Analog sensor reading

Table 8-26 3.3V Mgmt

Feature

Raw Value

Description

Sensor Name

3.3V Mgmt

-

Sensor LUN

0x00

-

Sensor Number

0x15

-

Entity ID

0x14

power module / DC-to-DC
converter

Sensor Type

0x02

Voltage

Event/Reading Type

0x01

Threshold

Assertion Event Mask
(Byte 15)

0x14 -

Assertion Event Mask
(Byte 16)

0x6A -

Table 8-25 3.3V (continued)

Feature

Raw Value

Description

This manual is related to the following products: