Table 8-43, Boot bank, Fru information and sdr summary – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual
Page 202

FRU Information and SDR Summary
ATCA-7368 Installation and Use (6806800M12D)
202
Entity ID
0x14
power module / DC-to-DC
converter
Sensor Type
0x08
Power supply
Event/Reading Type
0x6F
Sensor-specific
Assertion Event Mask
(Byte 15)
0x03 -
Assertion Event Mask
(Byte 16)
0x00 -
Deassertion Event Mask
(Byte 17)
0x00 -
Deassertion Event Mask
(Byte 18)
0x00 -
Threshold Mask (Byte 19) 0x03
-
Threshold Mask (Byte 20) 0x00
-
Base Unit
0x00
(unspecified)
Rearm mode
0x01
Auto
Hysteresis Support
0x00
No Hysteresis or
unspecified
Threshold Access
Support
0x00 No
Thresholds
Event Message Control
0x01
Entire Sensor only
Reading Definition
-
-
Table 8-43 Boot Bank
Feature
Raw Value
Description
Sensor Name
Boot Bank
-
Sensor LUN
0x00
-
Sensor Number
0x26
-
Entity ID
0xA0
PICMG Front Board
Table 8-42 Power Good (continued)
Feature
Raw Value
Description