Table 8-10, 48v amps, Fru information and sdr summary – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual
Page 159
![background image](https://www.manualsdir.com/files/772447/content/doc159.png)
FRU Information and SDR Summary
ATCA-7368 Installation and Use (6806800M12D)
159
Base Unit
0x04
Volts
Rearm mode
0x01
Auto
Hysteresis Support
0x01
Readable
Threshold Access
Support
0x02
Readable and settable
Event Message Control
0x00
Per Threshold/Discrete
State
Nominal Reading
0x94
48.1
Upper non-recoverable
threshold
0xE2 73.45
Upper critical threshold
0xDF
72.475
Upper non-critical
threshold
0x00 (unspecified)
Lower non-recoverable
threshold
0x74 37.7
Lower critical threshold
0x78
38.9
Lower non-critical
threshold
0x00 (unspecified)
Reading Definition
Analog reading byte
Analog sensor reading
Table 8-10 -48V Amps
Feature
Raw Value
Description
Sensor Name
-48V Current
-
Sensor LUN
0x00
-
Sensor Number
0x05
-
Entity ID
0x0A
Power Supply
Sensor Type
0x03
Current
Table 8-9 -48V B Volts (continued)
Feature
Raw
Value
Description