9 set handle switch command, 10 get payload communication time-out command, Table 7-39 – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual
Page 137: Set handle switch command description, Table 7-40, Set handle switch command, Ime-out, Supported ipmi commands
Supported IPMI Commands
ATCA-7368 Installation and Use (6806800M12D)
137
7.5.9
Set Handle Switch Command
The Set Handle Switch command sets the state of the hot-swap handle switch in (manual)
standalone mode (for a description refer to
).
7.5.10 Get Payload Communication Time-Out Command
The Get Payload Communication Time-Out command reads the payload communication
time-out value.
Table 7-39 Set Handle Switch Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
4
FRU ID (specify as 0)
5
Handle Switch Status
0x00: The handle switch is open.
0x01: The handle switch is closed.
0x02: The handle switch state is read from hardware.
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
Table 7-40 Get Payload Communication Time-Out Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
Response Data
1
Completion Code