Table 8-24, Fru information and sdr summary – Artesyn ATCA-7368 Installation and Use (June 2014) User Manual
Page 182
FRU Information and SDR Summary
ATCA-7368 Installation and Use (6806800M12D)
182
Table 8-24 12.0V
Feature
Raw Value
Description
Sensor Name
12.0V
-
Sensor LUN
0x00
-
Sensor Number
0x13
-
Entity ID
0x14
power module / DC-to-DC
converter
Sensor Type
0x02
Voltage
Event/Reading Type
0x01
Threshold
Assertion Event Mask
(Byte 15)
0x14 -
Assertion Event Mask
(Byte 16)
0x6A -
Deassertion Event Mask
(Byte 17)
0x14 -
Deassertion Event Mask
(Byte 18)
0x6A -
Threshold Mask (Byte 19) 0x36
-
Threshold Mask (Byte 20) 0x36
-
Base Unit
0x04
Volts
Rearm mode
0x01
Auto
Hysteresis Support
0x02
Readable and settable
Threshold Access
Support
0x02
Readable and settable
Event Message Control
0x00
Per Threshold/Discrete
State
Nominal Reading
0xCE
12
Upper non-recoverable
threshold
0xF0 13.9
Upper critical threshold
0xE5
13.3
Upper non-critical
threshold
0x00 (unspecified)