2.4.13 DOWNLINE PROGRAMMING OF FEATURE VALUE
FEATURES
The laser may change the value of features 2 through 24 via the communications
line by using an escape sequence. The format of the escape sequence is
ESC$Fnl;n2. where nl is the feature number and n2 is the value. For example,
ESC$F9;12. will set Feature 9 to a value of 12.
NOTE
Baud rate and tabs may not be set with this escape sequence.