Section 7.2- ENGINE DC CONTROL SYSTEM

TEST 15-CHECK

IGNITION SPARK

WEAK OR NO SPARK

SPARK

' G O O D ■

TEST 16-CHECK

SPARK PLUG

GOOD,

TEST 3- CHECK

POWER TO

FUEL PUMP

(NOTE 1)

TEST 17- CHECK

IGNITION POWER

SUPPLY (WIRE 14)

BAD

I

POWER TO PUMP GOOD

BUT PUMP DOESN’T WORK

i

■ GOOD

NO IGNITION
POWER SUPPLY

1

CLEAN AND REGAP

OR REPLACE
SPARK PLUG

REPLACE FUEL PUMP

TEST 18-CHECK

TEST 19-TEST

TEST 20- TEST

IGNITION

...........GOODii^

IGNITION

IGNITION

SENSOR

COIL

MODULE

b

I

d

b

I

d

b

I

d

DML

REPLACE SENSOR

I

REPLACE COIL

NO DC VOLTAGE TO FUEL PUMP ■

\

REPLACE

MODULE

TEST 21- CHECK

ENGINE

CONTROLLER

BOARD OUTPUT

TO WIRE 14

GOOD.

REPAIR RECONNECT

OR REPLACE BAD

WIRE(S)14AS

NECESSARY

NOTE 1:- For units with LP gas fuel

system, check for 12 VDC to the

gaseous fuel lockoff solenoid.

BAD<

REPLACE ENGINE CONTROLLER

CIRCUIT BOARD

f

POWER TO FUEL PUMP IS GOOD AND PUMP OPERATES ■

TEST 22- TEST

AUTOMATIC
CHOKE

GOODai.^

TEST 23- CHECK

CARBURETION

ADJUST OR REPAIR

^ CARBURETOR OR

ENGINE AS NECESSARY

BAD

ADJUST OR REPAIR

CHOKE SYSTEM

Page 7.2-3