Chapter 2: FUNCTIONS AND OPERATION
4.11. Paging Busy Input (only when the N-8000MI is used)
Busy status data from an airport broadcast system or similar large sound systems can be received when the
N-8000MI is interlocked with such systems, allowing important information to be accurately transmitted.
N-8000MI
Busy signal
Audio signal
Large airport broadcast
system, etc.
Note
Use the supplied N-8000 software to set the contacts to be used for paging busy input. (Refer to
4.10. Contact Bridge (only when the N-8000MI is used)
Contact signals can be transmitted by way of a network.
N-8000MI
N-8000MI
LAN
Contact input
Contact output
[Input interlock level]
ON
Input
OFF
ON
Output
OFF
[Input interlock edge]
ON
Input
OFF
ON
Output
OFF
50 ms
50 ms
50 ms
50 ms
Either of the following 2 control input's operation modes can be selected to perform this function.
Notes
• The input is defined when its level remains constant for 50 ms after change.
• Use the supplied N-8000 software to make settings for the contact bridge function. (Refer to