[Connecting to the PBX's analog E&M interface]
Connect the PBX's transmitting line to the unit's RX terminal, and the PBX's receiving line to the TX terminal.
Also connect the PBX's M (Mouth) line to the unit's E (Ear) terminal, and the PBX's E line to the M terminal.
CH1
TX
RX
C
M
TX
RX
C
E
M
E
CH2
N-8000MI's PBX interface terminal
To PBX analog E&M interface's transmitting line (T2)
To PBX's ground point
To PBX analog E&M interface's M and E lines
To PBX analog E&M interface's receiving line (R2)
2 channels
To PBX analog E&M interface's transmitting line (T1)
To PBX's ground point
To PBX analog E&M interface's M and E lines
To PBX analog E&M interface's receiving line (R1)
[Connecting to the Intercom's Tie-Line Unit]
Connect the intercom's transmitting line to the unit's RX terminal, and the receiving line to the TX terminal.
CH1
M
TX
RX
C
E
M
TX
RX
C
E
CH2
N-8000MI's PBX interface terminal
To Intercom's transmitting
line (T1)
To Intercom's receiving
line (R1)
To Intercom's transmitting
line (T2)
To Intercom's receiving
line (R2)
2 channels
Notes
• The "C" terminals for CH1 and CH2 are internally connected to the unit body (functional earth terminal).
• Do not ground the Functional earth terminal (No. 6 on
Tips
• Output level and input sensitivity can be adjusted in the range of 0 to 15 dB depending on the equipment to
be connected and cable length. (Refer to
• The Line attribute (Address signaling) and Line start method (Start dial supervision signaling) can be set for
the connected equipment. (Refer to
Tip
Output level and input sensitivity can be adjusted
in the range of 0 to 15 dB depending on the
equipment to be connected and cable length.
(Refer to