Function settings, P. 5-38 – Toa N-8000 Series Ver.1.41 User Manual
Page 182

5-38
Chapter 5: SYSTEM SETTINGS BY SOFTWARE
Chapter 5: SYSTEM SETTINGS BY SOFTWARE
Multi Interface: Function Settings
5.5.3. Function settings
Step 1. Click "Function Settings" tab to display the following setting screen.
Step 2. Set individual items.
(1) Oneshot make time (second)
Sets the duration that the external control output terminals are shorted momentarily when the door remote
control function is performed.
The setting range is from 0 to 9 (in 1-second units).
If not required, set the duration to "0."
(2) Time Limit
Set the time-out value for calling, conversation or paging functions in ten-second units between 10 and
990 seconds.
Call Time-out:
Set whether to limit the duration of a call to the station. If setting a timeout, enter
the time limit after which calls to the station are automatically terminated. If not
setting a timeout, calls will continue until they are cancelled or the called station
responds.
Conversation Time-out: Set whether to limit the duration of conversations with the station. If setting a
timeout, enter the time limit after which conversations to the station are
automatically terminated. If not setting a timeout, conversations will continue until
executing the termination operation.
Paging Time-out:
Set whether to limit the duration of paging call with the station. If setting a
timeout, enter the time limit after which paging calls to the station are
automatically terminated.
If not setting a timeout, paging calls will continue until executing the termination
operation.