Specifications – Toa N-8000 Series Ver.1.41 User Manual
Page 16

1-3
Chapter 1: GENERAL DESCRIPTION
4. SPECIFICATIONS
Number of Units Connectable to LAN: Maximum 80 (a total of Exchanges, Multi interface units and IP stations)
Line Capacity:
Maximum 1,280 (80 Exchanges x 16 stations per Exchange)
Speech Link Capacity:
Maximum 320 (80 N-8000EX Exchanges)
Single Exchange
N-8000EX:
4 links
N-8010EX:
1 link
Unit to unit
N-8000EX:
8 links
N-8010EX:
2 links
N-8000MI:
2 links
Speech:
Maximum 2 links
Audio input: Maximum 2 links
Audio output: Maximum 2 links
Note
The above links can be simultaneously used.
(Refer to the table on
Paging
Paging Zones:
Maximum 160
Paging Outputs:
Maximum 160 (When 80 N-8000EX Exchanges or Multi interface units
are connected)
N-8000EX:
2 outputs
N-8000MI:
2 outputs
Simultaneous access capacity for paging links:
N-8000EX:
Multicast paging: Maximum 4 links
Unicast paging:
1 link
N-8010EX:
Multicast paging: Maximum 2 links
Unicast paging:
1 link
N-8000MI:
Multicast paging: Maximum 2 links
Unicast paging:
1 link
N-8500MS:
Multicast paging: 1 link
Unicast paging:
1 link
Paging Destinations Via Network: Maximum 79 (Multicast paging), Maximum 16 (Unicast paging)
BGM:
Maximum 8 channels (Number of channels selectable at the station.)
PBX Interface:
Maximum 160
(When 80 Multi interface units are connected)
Tie-line Interface:
Maximum 160
(When 80 Multi interface units are connected)
External Contact Output:
Maximum 1,280 (When 80 Multi interface units are connected)
External Contact Input:
Maximum 1,280 (When 80 Multi interface units are connected)
System Settings:
Personal computer setting using a dedicated software program (over LAN)
(Network Related)
Voice Delay Time:
80 or 320 ms, selectable
Connection Delay Time:
Maximum 1 second (When Multicast paging is made to 79 zones)
Usage Bandwidth:
Maximum 2.08 Mbps (one way)/When Unicast paging is made to 16 zones
Maximum 130 kbps (two-way)/one call