N-8540ds connection, N-8540ds connections, P. 2-38, p. 2-39, p. 3-30 – Toa N-8000 Series Ver.1.41 User Manual
Page 126

3-30
Chapter 3: INSTALLATION & WIRING
4.4.2. N-8540DS connection
To network
To AC mains
+24 V DC
GND
+
-
N-8540DS rear
External
power supply
Relay
Diode
H C
LAN
Frame ground
1
2
3
Ground from the frame ground
when the switch box is not grounded.
1. AC adapter terminal connection
Connect the AC adapter*.
* Use the AC adapter AD-1210P (optional) or the
equivalent.
As for the usable adapter, consult your TOA
dealer.
2. Contact output terminal connection
An external relay can be connected as illustrated
above.
(Refer to
[Specification of contact output]
Open collector output
Withstand voltage: Max. 30 V DC,
Control current:
Max. 50 mA
3. Network connection terminal connection
Can be connected to a network of 10BASE-
T/100BASE-TX in auto-sensing.
Connecting the station to a PoE (Power over
Ethernet) switching hub compliant with
IEEE802.3af eliminates the need for an AC
adapter. (For connection, refer to the instruction
manual supplied with the switching hub.)
Use a straight through cable of UTP category 5 or
more for this connection.
Install the ferrite clamp (supplied with the N-
8540DS) on the network cable.
Ferrite clamp
(supplied with the N-8540DS)
Cable