Contact output setting, P. 5-44 – Toa N-8000 Series Ver.1.41 User Manual
Page 188

5-44
Chapter 5: SYSTEM SETTINGS BY SOFTWARE
Chapter 5: SYSTEM SETTINGS BY SOFTWARE
Multi Interface: Contact Output
5.5.6. Contact output setting
Step 1. Click on the Contact Output tab. The setting screen is displayed.
Step 2. Set each item of "Contact output."
Set the access number for the contact output terminal to be activated when the station performs
external equipment control (one-shot make output or make/break output).
(1) Access No. digit
Enter 2 – 4 digit numbers to be used when controlling external equipment at the station.
(2) Contact output No. (Can't be edited.)
The Multi interface unit's contact output terminal number.
(3) Access No.
Set the access number of the digit set in "Access No. digit", which is used to control external equipement
at the station.
(4) Line status
Select the line to be diagnosed.
The specified contact output terminal is closed when such status is judged abnormal that the CPU failure
is detected on the line or the line is not connected though the station number has been registered.
(5) Network status
Select the equipment to be diagnosed.
The specified contact output terminal is closed when the equipment is judged failed if no response is
detected from it.