beautypg.com

Indicator state at the time of emergency reset – Toa SX-2000 Series Manual User Manual

Page 91

background image

8-13

Chapter 8: RM-200SF FIREMAN'S MICROPHONE

2.12. Indicator State at the Time of Emergency Reset

When the system is set to "Emergency," the emergency reset function can be assigned to the Function key.
Pressing the function-assigned key causes all the activated emergency broadcast patterns to stop, allowing
the emergency broadcast status to be reset after the reset EV message broadcast completion.
The 2 indicators next to the Function key indicate the emergency reset state.

Notes
• For the emergency function settings, refer to the separate Setting Software Instructions, "Basic Settings."
• For instructions on assigning functions to function keys, see the separate Setting Software Instructions,

"Event Settings."

Indicator

Status

Meaning

This Emergency reset key is not pressed.

Reset EV Message broadcast assigned to this Emergency
reset key is being stopped.

Reset EV Message broadcast assigned to this Emergency
reset key is being activated.

Key ON/OFF Indicator

Reset EV Message
Status Indicator

Unlit

Lights green

This Emergency reset key is pressed.
(as long as it is pressed)

Lights green

Unlit

Reset EV Message Status Indicator

Key ON/OFF Indicator

Function key (Emergency reset key)

The meanings of the 2 indicators next to the Function Key are as follows: