Chapter 10: OPERATION

7.4. SX-2000SM's Operation Example

When the failure is detected, the built-in buzzer sounds, and the GENERAL indicator on the front panel
flashes.

Flashes

SX-2000SM

Step 1. Press the FAULT ACK key to acknowledge the failure.

The buzzer stops sounding, and the GENERAL indicator switches from flashing to steady on.

Yellow

Step 2. Locate the cause, then remove it.

Remove the CF card inserted into the SX-2000SM, connect it to a PC and read the log data using the
SX-2000 Setting Software. (For information about storing log data on a CF card, see

p. 1-5,

"Outputting Log Data."

)

Tip: Log data are confirmed online by establishing communications between the SX-2000SM and a

PC. For details, refer to the separate Setting Software Instructions, "Utility."

Confirm the cause of failure or abnormality on the log data (in this example, the log data that the
speaker terminal for the zone 2F is open state is listed), then fix the fault part.

Note
For most failure indications, the failure LED automatically goes off when the cause has been
corrected. For certain other failure indications, such as power amplifier failure or speaker shorts, the
LED does not automatically go off. In such cases, FAULT RESET key needs to be pressed.

Notes
When the failure reception function has been assigned to the control input terminal on the rear

panel of the SX-2000SM, SX-2100AI, SX-2000AO, SX-2100AO, or SX-2000CI, it is also possible to
receive a system failure via control input. For details, refer to the separate Setting Software
Instructions, "Event Settings."

It is also possible to receive a system failure by shorting the Data input terminals (ACK terminals)

on the rear panel of the SX-2000SM.