Chapter 4: SX-2000AO AUDIO OUTPUT UNIT

[Fluorescent Display]

COM

FAULT

KEYLOCK

EMERGENCY

OL

0

–10
–20
–30
–40

OL

0

–10
–20
–30
–40

FADER

LEVEL

LEVEL

1

2

3

4

5

6

7

8

1

2

21

22 23 24

25

26

29

30

31 32 33

34 35

36

3

3

27

28

21. Text Display Area

Displays the menu screen information when the
corresponding function key is pressed.

22. COM Indicator [COM]

Flashes to indicate a communications error.

23. Fault Indicator [FAULT]

Flashes when a system failure, incorrect system
configuration*

1

or communications error is

detected. This indicator continues to flash until
failure conditions return to normal.

*

1

When the system or module configuration
differs from the contents set by the SX-2000
Setting Software.

24. Output Level Meter Fader Indicator [FADER]

Lights when the output level meter indicates the
sound volume set using the SX-2000 Setting
Software or output volume control.

25. Output Level Meter Level Indicator [LEVEL]

Lights when the output level meter indicates the
level being output from the SX-2000AO.

26. Output Level Meter Scale

27. Output Indicator

The output channel to be monitored lights red.

28. Output ON/OFF Indicator

Indicates the unit's operating status when the
corresponding channel key is pressed.
The indicator state differs depending on the
function assigned to each channel key as
follows.

* The indicator state is "Unlit" when the output volume is muted.

29. Output Level Meter

Indicates the actual level or a set volume value
on each output channel.

Notes
• A timer-activated light shutoff function can be set for the fluorescent display using the SX-2000 Setting

Software. (See the separate Setting Software Instructions, "Basic Settings.")
When the light shutoff function has been set, if the SX-2000AO is not operated for 5 minutes or more, the
fluorescent display's light goes off and the standby indicator (11) begins to flash. Pressing any keys other
than the function keys on the front panel resets the screen display.

• Normally, the fluorescent display's light goes off at the time of the power failure.
• While the SX-2000 system is in an emergency condition, the fluorescent display's light does not go off even

if the power fails.

Function assigned to the channel key When ON When OFF

Output ON/OFF

Lights*

Unlit

General-purpose pattern broadcast's

Flashes

Lights