beautypg.com

KEYENCE LS-3100/3100W Series User Manual

Page 9

background image

3

CHAPTER 1 Preparation for Measurement

LS-3032/3034/3036

LS-3032/3034/3036

LS-3033/3033SO(8073)

LS-3033/3033SO(8073)

LS-3060

LS-3060

Laser emission

Laser emission

Laser emission

1-5 Safety Features Provided with the LS-3100(W) Series

The LS-3100(W) series has the following safety features:

Laser ON alarm LED
Both the sensor head and the controller panel have a visible LED that lights
when laser is ready to be and is being emitted.

LEDs can be checked to see if they are lit even when you are wearing laser
protective glasses.

Delay of laser beam emission
To prevent an operator from being exposed to the laser beam, the laser
beam is emitted three seconds after the laser ON alarm LED lights.

Laser emission remote control input connector
The laser emission control connector is located on the rear panel of the
control unit. The laser can be turned on or off by a remote control signal
through this connector.

Key-operated power switch
The controller power switch can be locked using the attached key.
When the LS-3100(W) controller is OFF, the key can be removed.

Laser beam shield
The sensor head transmitter comes with a laser beam shield.

Cover is closed.

Cover is open.