13
CHAPTER 3 Quick Setup Procedures
When the measurement mode is set to "P-P", the displayed value is
retained until HOLD is pressed or until an external signal is input through
the hold synchronous input terminal.
3. Resetting displayed values (When 1. 2 3 4 5 appears on the main
display)
HOLD
HOLD
HOLD
Main display
The displayed
value is reset
to "0".
Measuring Target
Displacement within
the Measuring Range
■ Applications
• Measuring disk head movement
• Measuring camera lens movement
■ Setting
1. Initialize settings ("MEMORY INITIALIZED" is displayed.)
Follow the same procedure as that for "Gap Measurement 1".
To reset the current value to "0", press ZERO.
To reset the displayed value to "0" again, press ZERO twice.
+
T
R
–
ZERO
Measuring Edge
Movement
■ Applications
• Measuring paper feed for copying machines
• Controlling sheet edges
• Measuring dot printer wire movement
■ Setting
1. Initialize settings ("MEMORY INITIALIZED" is displayed.)
Follow the same procedure as that for "Gap Measurement 1".
To reset the current value to "0", press ZERO.
To reset the displayed value to "0" again, press ZERO twice.
–
+
T
R
ZERO