4 message communication, Communi cat in g wit h the l j -v700 0 ser ies – KEYENCE CB-EP100 User Manual
Page 92

- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -
3-4 Message Communication
3-68
3
Communi
cat
in
g wit
h the
L
J
-V700
0 Ser
ies
0EH
CC0H
device name
Indicates the device name.
R
STRING
CC1H
-
CE3H
Reserved
0EH
CE4H
Product code
Stores the product code of the mea-
suring instrument.
R
INT
CE5H
Revision
Stores the revision.
USINT[0]: Major revision
USINT[1]: Minor revision
R
struct of
USINT[2]
CE6H
Controller model
Indicates the measuring instrument
model.
R
STRING
CE7H
Series code
Indicates the series code.
R
INT
CE8H
Series version
Indicates the series version.
R
INT
CE9H
Device type
Indicates the device type.
R
INT
CEAH
Reserved
0EH
CEBH
Connected head
model [0]
Indicates the head model.
R
STRING
CECH
Connected head
model [1]
Indicates the head model.
R
STRING
CEDH
-
CF9H
Reserved
0EH
CFAH
Connected unit
model [0]
Indicates the connected unit model.
R
STRING
CFBH
Connected unit
model [1]
Indicates the connected unit model.
R
STRING
CFCH
-
CFFH
Reserved
4BH
None
Program switch
Specifies the number of the program
to change to.
W
UDINT
4CH
None
Error clear
Clears errors
-
-
4EH
None
Request to reflect
setting write area
Specifies the reflection destination
area.
W
UDINT
4FH
None
Update of setting
write area
Specifies Update source area.
W
UDINT
50H
None
Initialize specified
program number
settings
Program number
W
UDINT
57H
None
Profile data con-
firmed
Copies the latest profile data to the
areas that can be acquired with the
attribute IDs 370H to 39FH.
R
UDINT
58H
None
Daily settings
Date and time information
W
struct of
UDINT[7]
59H
None
Acquires date
and time
Date and time information in service
response
R
struct of
UDINT[7]
5FH
None
Initializes all set-
tings
Returns the all settings to their default
values.
-
-
Service
code
(hexadecimal)
Attribute
ID
(hexadecimal)
Name
Description and service data
Attribute