beautypg.com

2 cb-ep100 ethernet/ip communication function, Overview of communication methods, Overview of communication methods -3 – KEYENCE CB-EP100 User Manual

Page 27: Cb-ep100 ethernet/ip communication function -3, Cb-ep100 ethernet/ip communication function

background image

3-3

3

Communi

cat

in

g wit

h the

L

J

-V700

0 Ser

ies

- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -

3-2

CB-EP100 EtherNet/IP Communication Function

This section describes the EtherNet/IP functions supported by the CB-EP100.
The CB-EP100 functions as an EtherNet/IP adaptor, and supports both cyclic and
message EtherNet/IP communications.

The EtherNet/IP scanner can use the following functions:

IN area

OUT area

Control status

Current value

Error information

Control data

EtherNet/IP scanner

CB-EP100

Measuring instrument

Message communication

Output

Judgement results

࡮࡮࡮࡮࡮࡮

Error information

IN area

OUT area

Direct read/write of various parameters

Cyclic communication

Control input

Setting value

Cyclic communication

Overview of Communication Methods

Available functions

Communication method

Cyclic communication

(Page 3-5)

Message Communication

(Page 3-28)

Clearing system errors

{

{

Reading system status

Reading error codes

Reading OUT measurement values

Reading judgment results

Reading OUT measurement value
status

Reading measuring instrument
control status

Inputing control data

Reading current program number

Switching the programs

Reading number of storage points

Writing/reading OUT measurement
setting

X

{

Reading profile data

Reading auto-zero reference value

Writing/reading controller device
name

Reading controller/sensor head type