KEYENCE CB-EP100 User Manual
Page 109

3-4 Message Communication
3-85
3
Communi
cat
in
g wit
h the
L
J
-V700
0 Ser
ies
- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -
(11)Acquire date and time
Message communication acquires the date and time in a measuring instrument
connected to the CB-EP100.
Service code 59H is used.
The following settings are required to use this object.
• Service code
• Class ID
• Instance ID
• Commands
• Response (when successful)
• Response (when failed)
Item
Description
Data Example
Service code
Specify "Acquire date and time (59H)" (fixed value).
59H
Class ID
CB Object (6BH) is specified (fixed value).
6BH
Instance ID
01H becomes a fixed value.
01H
Attribute ID
There is no attribute ID.
-
Service data
There is no data
-
Item
Description
Data Example
General status
Message communication returns status (00H) to notify
normal termination.
00H
Service response data
Returns the date and time.
Data length,
year, month,
day, hour,
minute, second
Item
Description
Data Example
General status
Message communication returns a general status.
05H
Additional status
Returns the additional status.
-
Service response data