Configuring message communication – KEYENCE CB-EP100 User Manual
Page 53

3-4 Message Communication
3-29
3
Communi
cat
in
g wit
h the
L
J
-V700
0 Ser
ies
- EtherNet/IP Network Unit CB-EP100 User’s Manual (LJ-V7000 Edition) -
The following settings are required to execute message communication with the CB-EP100.
[CB-EP100]
The CB-EP100 does not require any setting.
[Scanner]
Set the applicable service, Class ID, Instance ID, Attribute ID, and service data, and
send the commands used for message communication.
Refer to the scanner manual for details on the setting methods and applicable
commands.
The following lists the contents that can be executed by message communication
when the objects (CB Object) and services unique to the CB-EP100 are used.
(1) Read setting values
(2) Write setting values
(3) Switch programs
(4) Clear errors
(5) Input control data
(6) Request to reflect setting write area
(7) Update setting write area
(8) Initialize program settings
(9) Confirm profile data
(10) Set date and time
(11) Acquire date and time
(12) Initializes all settings
(1) Reading setting values from a measuring instrument
Message communication reads parameters from the CB-EP100 or from a
measuring instrument connected to the CB-EP100.
"(1) Reading setting values from a measuring instrument" (Page 3-74)
Configuring Message Communication
Actions which can be Completed with Message Communication
Command
Response:
123456
Current program No. OUT1
offset value for a measuring
instrument: 123456
CB-EP100
Scanner
Service code: 0EH
Class ID: 6BH
Instance ID: 01H
Attribute ID: 2456(998H)
Measuring
instrument