System alarms & logs, 0 system alarms, Chapter 6 system alarms & logs – CANOGA PERKINS 9145E NID Software Version 3.0 User Manual
Page 85
System Alarms & Logs
9145E NID Software User’s Manual
71
6.0 System Alarms
Use the System Alarms Screen to view alarms and faults on the 9145E.
To view alarm status, select System Alarms (4) from the Main Menu and press Enter. The
System Alarms Screen (Figure 6-1) opens. Press Esc to return to the Main Menu.
Figure 6-1 System Alarm Screen
Canoga Perkins Corp. Ethernet Network Interface Device 15-JUN-2009
Model 9145E-101-3-0 V43.16 F217 14:44:49
-------------------------------------SYSTEM ALARMS-----------------------------
Link Remote Fault SFP Transmitter
User Port Up N/A N/A
Network Port Up No OK
MP Port Disabled N/A N/A
MGMT UTP Port Disabled
Link Loss Fwd User->Net No
Link Loss Fwd Net->User No
48V DC Power Supply A Status OK 5.25 Volts Output (4.83 < OK < 5.49)
48V DC Power Supply B Status OK 5.28 Volts Output (4.83 < OK < 5.49)
Main Board Voltages All mainboard voltages OK
Fan Status Both Fans Ok
Temperature Status OK 26.0C (0.0C < OK < 70.0C)
Hit 'ESC' to return to previous menu
------------------------------------Messages-----------------------------------
-
Chapter 6
System Alarms & Logs