4 trap table, Trap table – CANOGA PERKINS 9145E NID Software Version 3.0 User Manual

Page 29

background image

System Configuration

9145E NID Software User’s Manual

IP/SNMP Agent Configuration

15

3.1.4 Trap Table

The Trap Table menu (Figure 3-7), is used to configure the SNMP Trap Managers. The following
section describes how to add new Managers, edit existing Managers, or to delete selected
Managers.

To Add a Managing Host IP, using the Space Bar, select Add (A) and press Enter.

To Edit a Managing Host, select Edit (E) and using the Space Bar select a Host IP address. The
Edit Trap/Notification menu (Figure 3-6) opens.

To Delete a Managing Host IP, using the Space Bar, select Delete (D) and select a Host IP
address.

1. Type in the Host IP address to add to the Trap/Notification Destination Table, and press

Enter.

2. Enter the Trap/Notification Port, the default value is 162 for regular SNMP managers, 163

should be for CanogaView. Any port numbers from 1 to 65535 can be used to receive
traps. Check with your IT manager to ensure the port setting is correct.

NOTE: Each Notification Type has a different configuration procedure. Follow the

specific procedure for the Notification Type selected.

Figure 3-7 Trap/Notification Destination Table Menu

Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
Model 9145E-101-3-0 V43.08 F211 11:53:23
---------------------TRAP/NOTIFICATION DESTINATION TABLE-----------------------
Managing Trap Username/ Security
Host Port Type Community Level

172.002.015.032 162 V2c-Inform Private N/A
172.002.145.011 162 V3-Trap admin Auth/Priv
172.016.002.034 162 V3-Inform admin Auth/Priv
172.016.150.014 162 V1-Trap public N/A

Select [(A)dd, (D)elete, (E)dit, (M)ore]:

------------------------------------Messages-----------------------------------