beautypg.com

CANOGA PERKINS 9145E NID Software Version 3.0 User Manual

Page 35

background image

System Configuration

9145E NID Software User’s Manual

Trap Configuration

21

The System Log contains the log of all enabled Trap events.

1. To configure Traps, select Trap Configuration (2) from the System Configuration menu.

The Trap Configuration menu (Figure 3-13) opens.

2. Select the number of the trap group to change and press Enter. Cycle through the Log

Only, Send Only, Both Log And Send, or Disabled parameters using the Space Bar.

The Master Trap Control setting will override all other trap settings. For example, if the Master
Trap Control is set to Log Only, rather than set to Both Log And Send (as shown), all the other
traps will only log alarm events, regardless of the individual trap settings. If the Master Trap
Control is set to Log And Send, the individual traps will perform according to their individual
settings. Setting the Master Trap Control setting to Disabled will disable all traps.

3. Press Enter to close the editing function and then press Esc to return to the System

Configuration menu.

NOTE: The setting of the Master Trap Control will override all other trap settings.

cpTemperatureOverHighThresholdAlarm

cpStatus.my

cpTemperatureHighThresholdAlarmCleared cpStatus.my

cpTemperatureWarningApproachingHigh-
Threshold

cpStatus.my

cpTemperatureHighThresholdWarning-
Cleared

cpStatus.my

cpTemperatureAlarmUnderLowThreshold cpStatus.my

cpTemperatureLowThresholdAlarmCleared

cpStatus.my

cpTemperatureWarningApproachin-
gLowThreshold

cpStatus.my

cpTemperatureLowThresholdWarning-
Cleared

cpStatus.my

SFP Traps cpSfpRemoved

cpSfpStatus.my

cpSfpInsertedInvalid

cpSfpStatus.my

cpSfpInsertedValid

cpSfpStatus.my

cpSfpTxOk

cpSfpStatus.my

cpSfpTxWarning

cpSfpStatus.my

cpSfpTxFailure

cpSfpStatus.my

Trap Config Item

Traps Affected

MIB Location