beautypg.com

CANOGA PERKINS 9145E NID Software Version 3.0 User Manual

Page 148

background image

9145E NID Software User’s Manual

Service OAM

Maintenance End Points

134

5. In the Admin Status field, select Enabled or Disabled and press . The Direction

field is highlighted.

6. In the Direction field, select Up to identify a MEP that transmits CFM PDUs towards, and

receives them from, the direction of NID interworking. Select Down to identify a MEP that
receives CFM PDUs from, and transmits them towards, the direction of the wire. Press
. The Port field is highlighted.

7. In the Port field, select User or Network.

8. To accept the new Maintenance End Point settings, type A and press . The Main-

tenance End Point Attributes screen (Figure 11-21 for 802.1ag or Figure 11-22 for Y.1731)
opens.

9. To modify an attribute value, type the number of the attribute and press , or press

to return to the Maintenance End Point List screen.

Figure 11-19. Create a New Maintenance End Point screen (Y.1731)

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
Model 9145E-104-0-0 V3.00 F214 05:15:27
----------------------CREATE A NEW MAINTENANCE END POINT------------------------

1) MA ID 0
MEP ID: 0
2) Admin Status: Disabled
3) Direction: Down
4) Port: User

Enter number in range 1 - 65535, or (CTRL-L) to select from list.

------------------------------------Messages-----------------------------------