CANOGA PERKINS 9145E NID Software Version 3.0 User Manual
Page 148
9145E NID Software User’s Manual
Service OAM
Maintenance End Points
134
5. In the Admin Status field, select Enabled or Disabled and press
field is highlighted.
6. In the Direction field, select Up to identify a MEP that transmits CFM PDUs towards, and
receives them from, the direction of NID interworking. Select Down to identify a MEP that
receives CFM PDUs from, and transmits them towards, the direction of the wire. Press
7. In the Port field, select User or Network.
8. To accept the new Maintenance End Point settings, type A and press
tenance End Point Attributes screen (Figure 11-21 for 802.1ag or Figure 11-22 for Y.1731)
opens.
9. To modify an attribute value, type the number of the attribute and press
Figure 11-19. Create a New Maintenance End Point screen (Y.1731)
Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
Model 9145E-104-0-0 V3.00 F214 05:15:27
----------------------CREATE A NEW MAINTENANCE END POINT------------------------
1) MA ID 0
MEP ID: 0
2) Admin Status: Disabled
3) Direction: Down
4) Port: User
Enter number in range 1 - 65535, or (CTRL-L) to select from list.
------------------------------------Messages-----------------------------------