Service OAM
9145E NID Software User’s Manual
SOAM Configuration
119
Figure 11-7. SOAM System Level Configuration screen
8. If you chose Locally Assigned in step 4, type 3 and press
9. To enable Sender ID TLV to be sent for connectivity check (CC) messages, type 4 and
press
10. To enable Sender ID TLV to be sent for loopback messages (LBM), type 5 and press
11. To enable Sender ID TLV to be sent for a linktrace reply (LTR), type 6 and press
Select Enabled or Disabled and press
12. To change the Port ID TLV Type for the User port, type 7 and press
MAC Address, or Locally Assigned, and press
13. To change the Port ID TLV Type for the Network port, type 8 and press
None, MAC Address, or Locally Assigned, and press
14. If you selected Locally Assigned in step 9, you can change the Port ID TLV Value for the
User port. Type 9 and press
15. If you selected Locally Assigned in step 10, you can change the Port ID TLV Value for the
Network port. Type 10 and press
16. Type A to accept the new settings and press
17. Press
Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
Model 9145E-104-0-0 V3.00 F214 05:15:27
-----------------------SOAM SYSTEM LEVEL CONFIGURATION--------------------------
1) Service OAM: Enabled
SENDER ID TLV
2) Chassis ID Format: 4 - MAC address
3) Chassis ID Value: 00:40:2A:02:68:60
Management Address Domain: SNMPoverIPv4
Management Address: 172.16.142.195
Sender ID TLV applicability:
4) CC: Enabled 5) LBM: Disabled 6) LTM: Enabled
PORT ID TLV USER PORT NETWORK PORT
Type: 7) 3 - MAC address 8) 7 - Locally assigned
Value: 9) 00:40:2A:02:68:63 10)
11) Configuration Error List
Select [1-11]:
------------------------------------Messages-----------------------------------