2 trap configuration, Trap configuration – CANOGA PERKINS 9145E NID Software Version 3.0 User Manual
Page 34
![background image](/manuals/651386/34/background.png)
9145E NID Software User’s Manual
System Configuration
Trap Configuration
20
3.2 Trap Configuration
Trap configuration defines how various alarms events are handled. Traps can be configured to be
logged, sent to the SNMP managers in the Trap Notification/Destination Table, or both logged
and sent for each event. Traps can also be set to Disabled. Individual traps are grouped together
for convenience.
Trap Config Item
Traps Affected
MIB Location
Master Trap Control All
User Port Link Traps
linkUp (User Port)
ifmib.my
linkDown (User Port)
ifmib.my
Network Port Link
Traps
linkUp (Network Port)
ifmib.my
linkDown (Network Port)
ifmib.my
Remote Fault Traps cp9145EPortRemoteFaultReceived cp9145EStatus.my
cp9145EPortSendingRemoteFault
cp9145EStatus.my
cp9145EPortRemoteFaultCleared
cp9145EStatus.my
Link Loss Forwarding
Traps
cp9145EPortLLFActivated
cp9145EStatus.my
Cold Start Traps coldStart
v2-mib.my
Authentication Traps cpAuthenticationFailure
cpMgmtStatus.my
Diagnostic Traps cpPortLoopbackOn
cpLoopback.my
cpPortLoopbackOff
cpLoopback.my
Entity Configuration
Traps
entConfigChange
EntityMib.my
Fan/Power/
Temperature Traps
cpMainBoardVoltageLevelsOK
cpStatus.my
cpMainBoardVoltageLevelsOutOfRange
cpStatus.my
cpDyingGasp
cpPowerSupply.my
cpPowerSupplyFailed
cpPowerSupply.my
cpPowerSupplyOverHighLimit
cpPowerSupply.my
cpPowerSupplyUnderLowLimit
cpPowerSupply.my
cpPowerSupplyOK
cpPowerSupply.my
cpFanShutDownDueToLowTemperature
cpFanStatus.my
cpFanOK
cpFanStatus.my
cpFanSlow
cpFanStatus.my
cpFanFailed
cpFanStatus.my