Service OAM
9145E NID Software User’s Manual
Service OAM
111
Figure 11-1. Positioning of UP/DOWN MEPs
11.1.2 Optional SOAM Configuration
Optionally, SOAM can be configured to send additional informations about the 9145E NID, using
Sender ID TLVs and/or Port ID TLVs.
Sender ID TLVs are optional extensions to SOAM packets, used to carry identification informa-
tion about the system that originates a particular packet. The system may be identified using a
textual string or a MAC or IP address associated with the NID. Details about Sender ID TLV con-
figuration are described in section 11.2
Sender ID TLVs may be included, based on configuration, in CCM, LBM, and LTM packets. The
far end system, upon receiving a packet containing a Sender ID TLV, parses and displays this
information, which better identifies a particular node. The 9145E NID displays the content or the
Sender ID TLVs received from far end system in the Connectivity Check Database (see section
11.6.5).
Port ID TLVs are optionally used for Linktrace reply messages, to identify a particular port on a
given system. Port ID TLVs received from the far end are displayed in the Linktrace monitoring
screen (see section 11.6.6.2).
9145 E NID
Forwarding Engine
USER port
Network port
Down MEP on USER port
UP MEP on USER port
Bidirectional traffic monitored
by the DOWN MEP
Bidirectional traffic monitored
by the UP MEP