2 monitoring a loopback request, 7 maintenance intermediate points, 1 display maintenance intermediate points – CANOGA PERKINS 9145E NID Software Version 3.0 User Manual
Page 160: Monitoring a loopback request, Maintenance intermediate points, Display maintenance intermediate points
9145E NID Software User’s Manual
Service OAM
Maintenance Intermediate Points
146
11.6.7.2 Monitoring a Loopback Request
1. To stop current Loopback processing, on the Loopback Monitoring screen (Figure 11-28
for unicast, Figure 11-29 for sweep, or Figure 11-30 for multicast), type S and press
2. To send another Loopback Request, type R and press
screen (Figure 11-31) opens.
3. To see more Multicast Loopback results, type N and press
4. Press
11.7 Maintenance Intermediate Points
Maintenance Intermediate Points (MIPs) are intermediate nodes within a Maintenance Domain or
Maintenance Entity Group. Up to 128 MIPs can be configured in a 9145E NID device.
11.7.1 Display Maintenance Intermediate Points
To display a list of existing MIPs, on the SOAM Configuration screen (Figure 11-6), type 6 and
press
Figure 11-31. Maintenance Intermediate Point List screen
Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
Model 9145E-104-0-0 V3.00 F214 05:15:27
---------------------MAINTENANCE INTERMEDIATE POINT LIST-----Display 1 - 3 of 3-
MIP ID LEVEL TYPE PORT MD/MEG NAME
1 0 802.1ag USER 2/
20 7 Y.1731 NETWORK 101/ag-comp-101
21 3 802.1ag NETWORK 1/Domain 1 (service)
Select [(F)irst, (P)rev, (N)ext, (L)ast] to change pages,
(A)dd new, (D)elete, (E)dit, ESC to return:
------------------------------------Messages-----------------------------------