beautypg.com

Smi timeout, Next steps, System event log cleared – Kontron S5500 SEL Troubleshooting User Manual

Page 93: 3 system event log cleared

background image

Miscellaneous events

System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards

84

Intel order number G74211-001

Revision 1.0

Byte

Field

Description

16

Event Data 3

Not used.

13.2.1

SMI Timeout – Next Steps

This event normally only occurs after another more critical event.

1. Check the SEL for any critical interrupts, memory errors, bus errors, PCI errors or any other serious errors.
2. If these are not present the system locked up before it was able to log the original issue. In this case, low level debug is normally required.

13.3 System Event Log Cleared

The BMC logs a SEL clear event. This would only ever be the first event in the SEL. Cause of this event is either a manual SEL clear using
Intel

®

SEL Viewer or some other IPMI aware utility, or is done in the factory as one of the last steps in the manufacturing process.

This is an informational event only.

Table 79: System Event Log Cleared Sensor Typical Characteristics

Byte

Field

Description

11

Sensor Type

10h =

Event Logging Disabled

12

Sensor Number

07h

13

Event Direction and
Event Type

[7] Event direction

0b = Assertion Event

1b = Deassertion Event

[6:0] Event Type = 6Fh (Sensor Specific)

14

Event Data 1

[7:6]

– 00b = Unspecified Event Data 2

[5:4]

– 00b = Unspecified Event Data 3

[3:0]

– Event Trigger Offset = 2 = Log area

reset/cleared

15

Event Data 2

Not used.