Smi timeout, Next steps, System event log cleared – Kontron S5500 SEL Troubleshooting User Manual
Page 93: 3 system event log cleared

Miscellaneous events
System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards
84
Intel order number G74211-001
Revision 1.0
Byte
Field
Description
16
Event Data 3
Not used.
13.2.1
SMI Timeout – Next Steps
This event normally only occurs after another more critical event.
1. Check the SEL for any critical interrupts, memory errors, bus errors, PCI errors or any other serious errors.
2. If these are not present the system locked up before it was able to log the original issue. In this case, low level debug is normally required.
13.3 System Event Log Cleared
The BMC logs a SEL clear event. This would only ever be the first event in the SEL. Cause of this event is either a manual SEL clear using
Intel
®
SEL Viewer or some other IPMI aware utility, or is done in the factory as one of the last steps in the manufacturing process.
This is an informational event only.
Table 79: System Event Log Cleared Sensor Typical Characteristics
Byte
Field
Description
11
Sensor Type
10h =
Event Logging Disabled
12
Sensor Number
07h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 6Fh (Sensor Specific)
14
Event Data 1
[7:6]
– 00b = Unspecified Event Data 2
[5:4]
– 00b = Unspecified Event Data 3
[3:0]
– Event Trigger Offset = 2 = Log area
reset/cleared
15
Event Data 2
Not used.