beautypg.com

Next steps – Kontron S5500 SEL Troubleshooting User Manual

Page 77

background image

PCI Express and Legacy PCI subsystem

System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards

68

Intel order number G74211-001

Revision 1.0

Table 68: Legacy PCI Error Sensor Event Trigger Offset

– Next Steps

Event Trigger Offset

Description

Next Steps

Hex

Description

04h

PERR#

Parity Error, PERR, asserted. This is a fatal error.

1. Decode bus, device, and function to identify the card.

2. If this is an add/in card:

a. Verify card is inserted properly.

b. Install the card in another slot and check if the error follows the card or stays with the slot.

c.

Update all firmware and drivers, including non-Intel

®

components.

3. If this is an onboard device:

a. Update all bios, firmware and drivers.

b. Replace the board.

05h

SERR#

System Error, SERR, asserted. This is a fatal error.