System Event Log Troubleshooting Guide for Intel

®

S5500/S3420 series Server Boards

Processor subsystem

Revision 1.0

Intel order number G74211-001

43

Table 45: Processor Status Sensors

– Next Steps

Sensor

Number

Sensor Name

Event Trigger Offset

Description

Next Steps

Hex

Description

60h

P1 Status

01h

Thermal trip

The processor exceeded the
maximum temperature.

This event normally only happens due to failures of the thermal solution:

1. Verify heatsink is properly attached and has thermal grease.

2. If system has a heatsink fan, ensure the fan is spinning.

3. Check all system fans are operating properly

4. Check that the air used to cool the system is within limits (typically 35°C)

07h

State Asserted

Indicates processor is present

61h

P2 Status

01h

Thermal trip

The processor exceeded the
maximum temperature.

07h

State Asserted

Indicates processor is present