Qpi correctable error sensor, Next steps – Kontron S5500 SEL Troubleshooting User Manual
Page 55

Processor subsystem
System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards
46
Intel order number G74211-001
Revision 1.0
8.4.1
QPI Correctable Error Sensor
The system detected an error and corrected it. This is an informational event.
Table 48: QPI Correctable Error Sensor Typical Characteristics
Byte
Field
Description
8
9
Generator ID
0033h = BIOS SMI Handler
11
Sensor Type
13h = Critical Interrupt
12
Sensor Number
06h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 72h (OEM Discrete)
14
Event Data 1
[7:6]
– 10b = OEM code in Event Data 2
[5:4]
– 00b = Unspecified Event Data 3
[3:0]
– Event Trigger Offset = Reserved
15
Event Data 2
0-3 = CPU1-4
16
Event Data 3
Not used.
8.4.1.1
QPI Correctable Error Sensor – Next Steps
This is an Informational event only. Correctable errors are acceptable and normal at a low rate of occurrence. If error continues:
1. Check the processor is installed correctly.
2. Inspect the socket for bent pins.
3. Cross test the processor if possible.