Processor subsystem

System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards

46

Intel order number G74211-001

Revision 1.0

8.4.1

QPI Correctable Error Sensor

The system detected an error and corrected it. This is an informational event.

Table 48: QPI Correctable Error Sensor Typical Characteristics

Byte

Field

Description

8

9

Generator ID

0033h = BIOS SMI Handler

11

Sensor Type

13h = Critical Interrupt

12

Sensor Number

06h

13

Event Direction and
Event Type

[7] Event direction

0b = Assertion Event

1b = Deassertion Event

[6:0] Event Type = 72h (OEM Discrete)

14

Event Data 1

[7:6]

– 10b = OEM code in Event Data 2

[5:4]

– 00b = Unspecified Event Data 3

[3:0]

– Event Trigger Offset = Reserved

15

Event Data 2

0-3 = CPU1-4

16

Event Data 3

Not used.

8.4.1.1

QPI Correctable Error Sensor – Next Steps

This is an Informational event only. Correctable errors are acceptable and normal at a low rate of occurrence. If error continues:

1. Check the processor is installed correctly.
2. Inspect the socket for bent pins.
3. Cross test the processor if possible.