Node manager exception event, Next steps, Node manager health event – Kontron S5500 SEL Troubleshooting User Manual
Page 100: 2 node manager health event

System Event Log Troubleshooting Guide for Intel
®
S5500/S3420 series Server Boards
Manageability Engine (ME) events
Revision 1.0
Intel order number G74211-001
91
15.1.1
Node Manager Exception Event – Next Steps
This is an informational event. Next steps will depend on the policy that was set. See the Node Manager Specification for more details.
15.2 Node Manager Health Event
A Node Manager Health Event message provides a run-time error indication about Intel
®
Intelligent Power Node Manager’s health. Types of
service that can send an error are defined as follows:
Misconfigured policy Error reading power data
Error reading inlet temperature
Table 86: Node Manager Health Event Sensor Typical Characteristics
Byte
Field
Description
8
9
Generator ID
002Ch
– ME Firmware
11
Sensor Type
DCh = OEM
12
Sensor Number
19h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 73h (OEM)
14
Event Data 1
[7:6]
– 10b = OEM code in Event Data 2
[5:4]
– 10b = OEM code in Event Data 3
[3:0]
– Health Event Type =02h (Sensor Node Manager)