beautypg.com

Node manager exception event, Next steps, Node manager health event – Kontron S5500 SEL Troubleshooting User Manual

Page 100: 2 node manager health event

background image

System Event Log Troubleshooting Guide for Intel

®

S5500/S3420 series Server Boards

Manageability Engine (ME) events

Revision 1.0

Intel order number G74211-001

91

15.1.1

Node Manager Exception Event – Next Steps

This is an informational event. Next steps will depend on the policy that was set. See the Node Manager Specification for more details.

15.2 Node Manager Health Event

A Node Manager Health Event message provides a run-time error indication about Intel

®

Intelligent Power Node Manager’s health. Types of

service that can send an error are defined as follows:

 Misconfigured policy Error reading power data
 Error reading inlet temperature

Table 86: Node Manager Health Event Sensor Typical Characteristics

Byte

Field

Description

8

9

Generator ID

002Ch

– ME Firmware

11

Sensor Type

DCh = OEM

12

Sensor Number

19h

13

Event Direction and
Event Type

[7] Event direction

0b = Assertion Event

1b = Deassertion Event

[6:0] Event Type = 73h (OEM)

14

Event Data 1

[7:6]

– 10b = OEM code in Event Data 2

[5:4]

– 10b = OEM code in Event Data 3

[3:0]

– Health Event Type =02h (Sensor Node Manager)