System Event Log Troubleshooting Guide for Intel

®

S5500/S3420 series Server Boards

Power Subsystems

Revision 1.0

Intel order number G74211-001

23

Sensor
Number

Sensor Name

Next Steps

1Eh

BB +1.35 P2 Mem

This 1.35V line is supplied by the main board.

This 1.35V line is used by low voltage memory on processor 2.

1. Ensure all cables are connected correctly.

2. Check the DIMMs are seated properly.

3. Cross test DIMMs

4. If the issue remains with the DIMMs on this socket, replace the main board, otherwise the DIMM.

4.2 Power Unit

The power unit monitors the power state of the system and logs the state changes in the SEL.

4.2.1

Power Unit Status Sensor

The power unit status sensor monitors the power state of the system and logs state changes. Expected power on events such as DC ON/OFF
are logged and unexpected events are also logged, such as AC loss and power good loss.

Table 15: Power Unit Status Sensors Typical Characteristics

Byte

Field

Description

11

Sensor Type

09h = Power Unit

12

Sensor Number

01h

13

Event Direction and
Event Type

[7] Event direction

0b = Assertion Event

1b = Deassertion Event

[6:0] Event Type = 6Fh (Sensor Specific)

14

Event Data 1

[7:6]

– 00b = Unspecified Event Data 2

[5:4]

– 00b = Unspecified Event Data 3

[3:0] = Sensor Specific offset as described in Table 9