Table 71: post error codes – Kontron S5500 SEL Troubleshooting User Manual
Page 81

System BIOS events
System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards
72
Intel order number G74211-001
Revision 1.0
Table 71: POST Error Codes
Error Code
Error Message
Response
0012
CMOS date/time not set
Major
0048
Password check failed
Major
0108
Keyboard component encountered a locked error.
Minor
0109
Keyboard component encountered a stuck key error.
Minor
0113
Fixed Media The SAS RAID firmware cannot run properly. The user should attempt to reflash the firmware.
Major
0140
PCI component encountered a PERR error.
Major
0141
PCI resource conflict
Major
0146
PCI out of resources error
Major
0192
Processor 0x cache size mismatch detected.
Fatal
0193
Processor 0x stepping mismatch.
Minor
0194
Processor 0x family mismatch detected.
Fatal
0195
Processor 0x Intel
®
QPI speed mismatch.
Fatal
0196
Processor 0x model mismatch.
Fatal
0197
Processor 0x speeds mismatched.
Fatal
0198
Processor 0x family is not supported.
Fatal
019F
Processor and chipset stepping configuration is unsupported.
Major
5220
CMOS/NVRAM Configuration Cleared
Major
5221
Passwords cleared by jumper
Major
5224
Password clear Jumper is Set.
Major
8160
Processor 01 unable to apply microcode update
Major
8161
Processor 02 unable to apply microcode update
Major
8180
Processor 0x microcode update not found.
Minor
8190
Watchdog timer failed on last boot
Major