Table 71: post error codes – Kontron S5500 SEL Troubleshooting User Manual

Page 81

background image

System BIOS events

System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards

72

Intel order number G74211-001

Revision 1.0

Table 71: POST Error Codes

Error Code

Error Message

Response

0012

CMOS date/time not set

Major

0048

Password check failed

Major

0108

Keyboard component encountered a locked error.

Minor

0109

Keyboard component encountered a stuck key error.

Minor

0113

Fixed Media The SAS RAID firmware cannot run properly. The user should attempt to reflash the firmware.

Major

0140

PCI component encountered a PERR error.

Major

0141

PCI resource conflict

Major

0146

PCI out of resources error

Major

0192

Processor 0x cache size mismatch detected.

Fatal

0193

Processor 0x stepping mismatch.

Minor

0194

Processor 0x family mismatch detected.

Fatal

0195

Processor 0x Intel

®

QPI speed mismatch.

Fatal

0196

Processor 0x model mismatch.

Fatal

0197

Processor 0x speeds mismatched.

Fatal

0198

Processor 0x family is not supported.

Fatal

019F

Processor and chipset stepping configuration is unsupported.

Major

5220

CMOS/NVRAM Configuration Cleared

Major

5221

Passwords cleared by jumper

Major

5224

Password clear Jumper is Set.

Major

8160

Processor 01 unable to apply microcode update

Major

8161

Processor 02 unable to apply microcode update

Major

8180

Processor 0x microcode update not found.

Minor

8190

Watchdog timer failed on last boot

Major