beautypg.com

Qpi fatal and fatal #2, Next steps – Kontron S5500 SEL Troubleshooting User Manual

Page 58

background image

System Event Log Troubleshooting Guide for Intel

®

S5500/S3420 series Server Boards

Processor subsystem

Revision 1.0

Intel order number G74211-001

49

Byte

Field

Description

13

Event Direction and
Event Type

[7] Event direction

0b = Assertion Event

1b = Deassertion Event

[6:0] Event Type = 74h (OEM Discrete)

14

Event Data 1

[7:6]

– 10b = OEM code in Event Data 2

[5:4]

– 00b = Unspecified Event Data 3

[3:0]

– Event Trigger Offset = Reserved

15

Event Data 2

0-3 = CPU1-4

16

Event Data 3

Not used.

8.4.3.1

QPI Fatal and Fatal #2 – Next Steps

This is an Informational event only. Correctable errors are acceptable and normal at a low rate of occurrence. If error continues:

1. Check the processor is installed correctly.
2. Inspect the socket for bent pins.
3. Cross test the processor if possible.