Qpi fatal and fatal #2, Next steps – Kontron S5500 SEL Troubleshooting User Manual
Page 58

System Event Log Troubleshooting Guide for Intel
®
S5500/S3420 series Server Boards
Processor subsystem
Revision 1.0
Intel order number G74211-001
49
Byte
Field
Description
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 74h (OEM Discrete)
14
Event Data 1
[7:6]
– 10b = OEM code in Event Data 2
[5:4]
– 00b = Unspecified Event Data 3
[3:0]
– Event Trigger Offset = Reserved
15
Event Data 2
0-3 = CPU1-4
16
Event Data 3
Not used.
8.4.3.1
QPI Fatal and Fatal #2 – Next Steps
This is an Informational event only. Correctable errors are acceptable and normal at a low rate of occurrence. If error continues:
1. Check the processor is installed correctly.
2. Inspect the socket for bent pins.
3. Cross test the processor if possible.